KHS Hygiene Flush Boxes

KHS Hygiene Flush Box PRO with flow sensor, single port, figure 689 03 007
KHS Hygiene Flush Box PRO with flow sensor, single port, figure 689 03 007- particularly suitable for buildings with special hygiene requirements
- to avoid stangnation acc. to standards and guidelines
- allows water exchange with turbulent flow in drinking water pipes up to DN 50
- Single port (water exchange group) for cold drinking water (PWC)
- for installation in all installation situations (flush or surface mounted)
- male union thread
- PRO control unit
- operation via WLAN (can be switched off) using the latest Access Point Technology
- seven timers for customised flushing strategy
- interval, time, volume, temperature and use-controlled flushing measures
- digital commissioning and maintenance assistant
- analysis and log readout via WLAN and USB
- visualised flushing history
- connection to KHS Mini Control-System possible
- networking of up to 60 Hygiene Flush Boxes possible

KHS Hygiene Flush Box PRO with flow sensor, double port, figure 689 03 008
KHS Hygiene Flush Box PRO with flow sensor, double port, figure 689 03 008- particularly suitable for buildings with special hygiene requirements
- to avoid stangnation acc. to standards and guidelines
- allows water exchange with turbulent flow in drinking water pipes up to DN 50
- double port (water exchange groups) for connection of e.g. PWC and PWH
- for installation in all installation situations (flush or surface mounted)
- male union thread
- PRO control unit
- operation via WLAN (can be switched off) using the latest Access Point Technology
- seven timers for customised flushing strategy
- interval, time, volume, temperature and use-controlled flushing measures
- digital commissioning and maintenance assistant
- analysis and log readout via WLAN and USB
- visualised flushing history
- connection to KHS Mini Control-System possible
- networking of up to 30 Hygiene Flush Boxes possible

KHS Hygiene Flush Box PURE, single port, figure 689 03 005
KHS Hygiene Flush Box PURE, single port, figure 689 03 005- Especially suitable for time-controlled interval flushing operation in small buildings
- to avoid stangnation acc. to standards and guidelines
- allows water exchange with turbulent flow in drinking water pipes up to DN 50
- Single port (water exchange group) for cold drinking water (PWC)
- for installation in all installation situations (flush or surface mounted)
- male union thread
- PURE control unit
- manual commissioning on the device by hand
- interval controlled flushing
- up to 100,000 event entries to verify use as intended (readout via USB)

KHS Hygiene Flush Box PURE, double port, figure 689 03 006
KHS Hygiene Flush Box PURE, double port, figure 689 03 006- Especially suitable for time-controlled interval flushing operation in small buildings
- to avoid stangnation acc. to standards and guidelines
- allows water exchange with turbulent flow in drinking water pipes up to DN 50
- double port (water exchange groups) for connection of e.g. PWC and PWH
- for installation in all installation situations (flush or surface mounted)
- male union thread
- PURE control unit
- manual commissioning on the device by hand
- interval controlled flushing
- up to 100,000 event entries to verify use as intended (readout via USB)

KHS Hygiene Flush Box LITE with flow sensor, single port, figure 689 03 009
KHS Hygiene Flush Box LITE with flow sensor, single port, figure 689 03 009- particularly suitable for safety-sensitive buildings
- to avoid stangnation acc. to standards and guidelines
- allows water exchange with turbulent flow in drinking water pipes up to DN 50
- Single port (water exchange group) for cold drinking water (PWC)
- for installation in all installation situations (flush or surface mounted)
- male union thread
- LITE control unit
- no integrated controller logic (control via direct connection of all components to BMS (24 V/4-20 mA)
- interval, time, volume, temperature and use-controlled flushing measures possible (depending on external flushing logic)

KHS Hygiene Flush Box LITE with flow sensor, double port, figure 689 03 010
KHS Hygiene Flush Box LITE with flow sensor, double port, figure 689 03 010- particularly suitable for safety-sensitive buildings
- to avoid stangnation acc. to standards and guidelines
- allows water exchange with turbulent flow in drinking water pipes up to DN 50
- double port (water exchange groups) for connection of e.g. PWC and PWH
- for installation in all installation situations (flush or surface mounted)
- male union thread
- LITE control unit
- no integrated controller logic (control via direct connection of all components to BMS (24 V/4-20 mA)
- interval, time, volume, temperature and use-controlled flushing measures possible (depending on external flushing logic)

KHS HS2®, hygiene-flushing box, single port, incl. cover panel, figure 689 03 001
KHS HS2®, hygiene-flushing box, single port, incl. cover panel, figure 689 03 001- to avoid stangnation acc. to standards and guidelines
- allows water exchange with turbulent flow in drinking water pipes up to DN 50
- Single port (water exchange group) for cold drinking water (PWC)
- connection to KHS Mini Control-System possible

KHS HS2®, hygiene-flushing box, with flow sensor, single port, incl. cover panel, figure 689 03 003
KHS HS2®, hygiene-flushing box, with flow sensor, single port, incl. cover panel, figure 689 03 003- to avoid stangnation acc. to standards and guidelines
- allows water exchange with turbulent flow in drinking water pipes up to DN 50
- Single port (water exchange group) for cold drinking water (PWC)
- connection to KHS Mini Control-System possible

KHS HS2®, hygiene-flushing box, with flow sensor, double port, incl. cover panel, figure 689 03 004
KHS HS2®, hygiene-flushing box, with flow sensor, double port, incl. cover panel, figure 689 03 004- to avoid stangnation acc. to standards and guidelines
- allows water exchange with turbulent flow in drinking water pipes up to DN 50
- double port (water exchange groups) for connection of e.g. PWC and PWH
- connection to KHS Mini Control-System possible