KHS Flow-Splitter
KHS Flow-Splitter unit - dynamic, for flush mounted installation, figure 650 00

KHS Flow-Splitter unit - dynamic, for flush mounted installation

figure 650 00

  • prevents stagnation in ring pipe installations through forced flow during downstream withdrawals, can be used in cold drinking water (PWC) and hot drinking water (PWH)
  • KHS Flow-Splitter - dynamic, according to the Venturi principle, including dynamic cartridge, flow and return branch for connection of outlets / plumbing units
  • wetted metal parts made from dezincification-free and corrosion-resistant gunmetal, resistant against aggressive water
  • maintenance free
  • including quarter turn stop valves, female threaded, for flush-mounted installation, figure 585 00
KHS Flow-Splitter unit - dynamic, FPT, figure 650 06

KHS Flow-Splitter unit - dynamic, FPT

figure 650 06

  • prevents stagnation in ring pipe installations through forced flow during downstream withdrawals, can be used in cold drinking water (PWC) and hot drinking water (PWH)
  • KHS Flow-Splitter - dynamic, according to the Venturi principle, including dynamic cartridge, flow and return branch for connection of outlets / plumbing units
  • wetted metal parts made from dezincification-free and corrosion-resistant gunmetal, resistant against aggressive water
  • maintenance free
  • including KHS stop valve, female threaded, figure 385 00
KHS Flow-Splitter unit - dynamic, union thread, figure 650 02

KHS Flow-Splitter unit - dynamic, union thread

figure 650 02

  • prevents stagnation in ring pipe installations through forced flow during downstream withdrawals, can be used in cold drinking water (PWC) and hot drinking water (PWH)
  • KHS Flow-Splitter - dynamic, according to the Venturi principle, including dynamic cartridge, flow and return branch for connection of outlets / plumbing units
  • wetted metal parts made from dezincification-free and corrosion-resistant gunmetal, resistant against aggressive water
  • maintenance free
  • including KHS stop valves, union thread, figure 386 0G
KHS Flow-Splitter set - dynamic, figure 650 20

KHS Flow-Splitter set - dynamic

figure 650 20

  • prevents stagnation in ring pipe installations through forced flow during downstream withdrawals, can be used in cold drinking water (PWC) and hot drinking water (PWH)
  • KHS Flow-Splitter - dynamic, according to the Venturi principle, including dynamic cartridge, flow and return branch for connection of outlets / plumbing units
  • wetted metal parts made from dezincification-free and corrosion-resistant gunmetal, resistant against aggressive water
  • maintenance free
KHS Flow-Splitter box, for in-floor installation, figure 640 50

KHS Flow-Splitter box, for in-floor installation

figure 640 50

  • for use exclusively in single and two-family houses
  • prevents stagnation in ring pipe installations through forced flow during downstream withdrawals, can be used in cold drinking water (PWC)
  • venturi technology creates parallel flow through main and loop pipe
  • for flush mounted installation or in unaccessible locations
  • maintenance free

KHS Flow-Splitter

Ensure lasting drinking water hygiene

The stage for ensuring sustainable and efficient drinking water hygiene has already been set when it comes to selecting the installation type. In ring installations, KHS Flow-Splitters make it possible to perform 100 water exchanges a day in potential stagnation areas without auxiliary energy or additional flushing measures. Natural draw-offs cause drinking water to be exchanged in all upstream bathrooms. And Flow-Splitter installations don’t just ensure drinking water hygiene through preventing stagnation, as comparatively up to 5K lower temperatures are achieved through regularly flowing fresh drinking water in the bathroom installation, ultimately making temperature maintenance < 25°C considerably more efficient.

In conjunction with additional system components such as the KHS Hygiene Flush Box or KHS CoolFlow the water exchange and temperature maintenance can even be implemented in phases of the interruptions to operations in an automated manner – sustainable, economical and resource-friendly.

How does a Flow-Splitter work?

Cross-software testing tool for testing Flow-Splitters

This tool is used to test the flow conditions in a flow-splitter loop. After inputting the ring loop pipe parameters, you can see the resulting flow conditions such as turbulence levels and flushing times from the overview at a glance.

Go to Flow-Splitter tool