Accessories for KHS

Aerator set for KHS Hygiene Flush Box PRO, PURE and LITE, figure 689 04 019

Aerator set for KHS Hygiene Flush Box PRO, PURE and LITE, figure 689 04 019
  • pressure independent limitation of flow
Aerator set for KHS Hygiene Flush Box PRO, PURE and LITE, figure 689 04 019

cover for KHS HS2® hygienie flushing box, figure 689 07 001

cover for KHS HS2® hygienie flushing box, figure 689 07 001
  • for covering KHS HS2® hygienic flushing box when surface mounted
cover for KHS HS2® hygienie flushing box, figure 689 07 001

CONTROL-PLUS flow measurement valve for KHS HS2® hygienie flushing box, figure 689 4G 001

CONTROL-PLUS flow measurement valve for KHS HS2® hygienie flushing box, figure 689 4G 001
  • wetted metal parts made from dezincification-free and corrosion-resistant gunmetal, resistant against aggressive water
  • for installation in KHS HS2® hygiene-flushing box
CONTROL-PLUS flow measurement valve for KHS HS2® hygienie flushing box, figure 689 4G 001

connection set surface-mounted CAN bus for KHS HS2® hygienie flushing box, figure 689 06 001

connection set surface-mounted CAN bus for KHS HS2® hygienie flushing box, figure 689 06 001
  • for connecting KHS HS2® hygienic flushing box to the KHS Mini Control System
connection set surface-mounted CAN bus for KHS HS2® hygienie flushing box, figure 689 06 001

connection set flush-mounted CAN bus for KHS HS2® hygienie flushing box, figure 689 06 002

connection set flush-mounted CAN bus for KHS HS2® hygienie flushing box, figure 689 06 002
  • for connecting KHS HS2® hygienic flushing box to the KHS Mini Control System
connection set flush-mounted CAN bus for KHS HS2® hygienie flushing box, figure 689 06 002

BMS connecting cable via digital I/O for KHS HS2® hygienie flushing box, figure 689 05 001

BMS connecting cable via digital I/O for KHS HS2® hygienie flushing box, figure 689 05 001
  • for connecting KHS HS2® hygienic flushing box to the KHS LOGIC control system or to the building management system (BMS) via digital I/O
BMS connecting cable via digital I/O for KHS HS2® hygienie flushing box, figure 689 05 001

service set (4, 10, 15 l/min) for KHS HS2® hygienie flushing box, figure 689 99 001

service set (4, 10, 15 l/min) for KHS HS2® hygienie flushing box, figure 689 99 001
  • pressure independent limitation of flow
  • 4 l/min, 10 l/min, 15 l/min
service set (4, 10, 15 l/min) for KHS HS2® hygienie flushing box, figure 689 99 001

Connection-set, figure 619 01 001

Connection-set, figure 619 01 001
  • for shut off for maintenance and repair
Connection-set, figure 619 01 001

Vibration damper set for chiller, figure 619 02 000

Vibration damper set for chiller, figure 619 02 000
  • vibration damper set for the KHS CoolFlow chiller for body and vibration isolation
  • consisting of 4 square mounting bases with die-cast-aluminium device fastening with rubber vibration element in between
Vibration damper set for chiller, figure 619 02 000

AC/DC converter, figure 686 01 001

AC/DC converter, figure 686 01 001
  • for the operation of the KHS full flow stop valve with spring-reset servo drive 24 V DC with 24 V AC supply voltage figur 686 01 
AC/DC converter, figure 686 01 001

KHS BACnet Gateway L for MASTER 2.0/2.1, figure 686 02 023

KHS BACnet Gateway L for MASTER 2.0/2.1, figure 686 02 023
  • interface device for the KHS MASTER 2.0/2.1 mini control system for connection to the building management system
  • protocol translation into in BACnet IP/MSTP
  • for flushing systems with up to 24 slaves
  • LAN RJ45 10/100 MBit/s Ethernet
  • installation on DIN TS35 top-hat rail in accordance with EN60715
KHS BACnet Gateway L for MASTER 2.0/2.1, figure 686 02 023

KHS BACnet Gateway XL for MASTER 2.0/2.1, figure 686 02 024

KHS BACnet Gateway XL for MASTER 2.0/2.1, figure 686 02 024
  • interface device for the KHS MASTER 2.0/2.1 mini control system for connection to the building management system
  • protocol translation into in BACnet IP/MSTP
  • LAN RJ45 10/100 MBit/s Ethernet
  • installation on DIN TS35 top-hat rail in accordance with EN60715
KHS BACnet Gateway XL for MASTER 2.0/2.1, figure 686 02 024

Modbus TCP/IP licence for MASTER 2.0/2.1, figure 99 3590

Modbus TCP/IP licence for MASTER 2.0/2.1, figure 99 3590
  • licence code for activating the Modbus TCP/IP protocol on the KHS MASTER 2.0/2.1 mini control system
  • enables connection to the building management system via Modbus TCP/IP
Modbus TCP/IP licence for MASTER 2.0/2.1, figure 99 3590

Data logger and gateway for KHS Cold Water Cooler, figure 611 00

Data logger and gateway for KHS Cold Water Cooler, figure 611 00
  • data logger and gateway for the KHS CoolFlow cooler for connection to the building management system
  • data storage on micro SD card, supplied
  • LAN RJ45 10/100 MBit/s Ethernet
Data logger and gateway for KHS Cold Water Cooler, figure 611 00

KHS CoolFlow cold water balancing valve, without actuator and flushing function, figure 617 0G

KHS CoolFlow cold water balancing valve, without actuator and flushing function, figure 617 0G
  • control range 15 °C - 22 °C
  • as an automatic circulation balancing valve
  • thermostatic balancing valve for cold water return branches with kv-min ≥ 0.03
  • wetted metal parts made from dezincification-free and corrosion-resistant gunmetal, resistant against aggressive water
  • male union thread
KHS CoolFlow cold water balancing valve, without actuator and flushing function, figure 617 0G